Adding new tables

...

Info

The PREPARE commands add supplemental logging to the table if it was not there yet. This can sometimes result in the ORA-01466 error while performing step 3.

If this happens, we recommend using the internal commands to prepare a new table. In following example, scott.emp table is prepared. It first adds the supplemental logging, then waits for the SCN to advance then it does the actual PREPARE: 

dbvrep>ENGINE SUPPLEMENTAL LOGGING TABLE SCOTT.EMP ENABLE PRIMARY KEY
dbvrep>ENGINE WAIT_SCN_FLIP
dbvrep>PREPARE TABLE SCOTT.EMP